DXWD Single Yoke Double Tuning Adjustable Air Gap Laboratory Electromagnet U Type Electromagnet
The magnetic field is both-way adjustable, it is a one yoke design, magnetic field direction is horizontal, Product up-right seat so that have a very wide working place to operation or connect with other equipment. so it is a very common design. Apply to Hall effect studies, magnetoresistance effect studies, magnetostriction studies, torque magnetometer, force method magnetometer, VSM, etc..
Name of parts
1: Horizontal yoke
2: Vertical yoke
3: coil
4: Pole Cap Surface
5: Pole Cap
6: Handle
7: Pole Sleeve
A: Coil Gap
B: Pole Gap
C: Center Height
D: Horizontal distance of Diameter
E: Coil Diameter
Main Dimension
Model
Pole Diameter
A
B
C
D
E
Weight
(mm)
(mm)
(mm)
(mm)
(mm)
(mm)
(Kg)
WD-50
50
80/Custom
0~80
145
130
180
40
WD-80
80
100/Custom
0~100
190
175
260
135
WD-100
100
120/Custom
0~120
200
200
300
200
WD-130
130
120/Custom
0~120
250
240
260
430
WD-175
175
120/Custom
0~120
300
310
470
630
WD-200
200
120/Custom
0~120
300
320
490
930
WD-220
220
120/Custom
0~120
310
330
610
1060
WD-250
250
120/Custom
0~120
320
350
540
1920
WD-280
280
150/Custom
0~120
360
380
670
2570
WD-300
300
150/Custom
0~120
360
400
740
3580
WD-380
380
200/Custom
0~120
495
440
850
6800
Technical Parameters
DXWD Single Yoke Double-tuned Air Gap Alterable Electromagnet
Model
Pole Diameter
Air Gap Range
Pole Face
Magnetic field index
Power
(mm)
(mm)
(mm)
Air Gap(mm)
Maxium Magnetic Field(T)
DXWD-50
Φ50
0-80
Φ50
10
0.9
0.3KW
DXWD-100
Φ100
0-80
Φ60
10
1.8
1.6KW
Φ100
20
1
DXWD-130
Φ130
0-100
Φ60
10
2.3
3.0KW
Φ120
30
1.2
DXWD-175
Φ175
0-120
Φ60
10
2.3
5.0KW
Φ100
50
1.25
Φ150
100
0.6
DXWD-200
Φ200
0-140
Φ60
10
2.6
8.0KW
Φ80
30
1.6
Φ140
70
0.9
DXWD-250
Φ250
0-140
Φ60
10
2.9
12.0KW
Φ80
40
1.9
Φ120
80
1.1
DXWD-280
Φ280
0-150
Φ70
10
3.1
16.0KW
Φ120
70
1.5
DXWD-380
Φ380
0-180
Φ100
40
2.2
20.0KW
Typical Cases
Model
Key Indicators
Reference Picture
DXWD-100
1, The electromagnet is a double-twisted single-yoke structure, the vertical seat, the magnetic field in the horizontal direction, the line spacing 100mm, pole diameter 100mm, magnetic field air gap adjustable range 0 ~ 100mm. 2, The diameter of the solenoid pole is 100mm, when the air gap is 10mm, the center magnetic field Hmax = 1.6T. 3, The electromagnetic use of natural cooling structure, when the magnetic pole spacing of 20mm, magnetic field ≥ 1.0T, the continuous working time of 30 minutes, the temperature is less than 30 ℃. 4, The electromagnet DC power supply is 1.6KW; (15A, 105V). 5, Electromagnet weight is about 200Kg
DXWD-50
1, The electromagnet is a double-twisted single-yoke structure, the vertical seat, the magnetic field in the horizontal direction, the line spacing 80mm, pole diameter 50mm, magnetic field air gap adjustable range 0 ~ 80mm. 2,The diameter of the pole is 50mm, when the air gap is 10mm, the central magnetic field Hmax = 1.0T. 3, The electromagnetic use of natural cooling structure, when the magnetic pole spacing of 10mm, magnetic field ≥ 1.0T, the continuous working time of 30 minutes, the temperature is less than 30 ℃, magnetic 0.6T can work for a long time. 4, The electromagnet DC power supply is 0.3KW; (10A, 30V). 5, The weight of the electromagnet is about 35Kg
DXWD-130
1, the electromagnet is a double-twisted single-yoke structure, the vertical seat is placed, the magnetic field is in the horizontal direction, the line spacing is 120mm, the pole diameter is 130mm, and the magnetic field air gap adjustable range is 0 ~ 120mm. 2, the diameter of the pole is 60mm, when the air gap is 10mm, the central magnetic field Hmax = 2.5T. 3, the electromagnetic use of natural cooling structure, when the magnetic pole spacing of 10mm, magnetic field ≥ 2.2T, the continuous working time of 30 minutes, the temperature is less than 30 ℃, 1.5T magnetic for a long time to work. 4, the electromagnet DC power supply is 3.8KW; (25A, 150V). 5, the weight of the electromagnet is about 430Kg